Dvb01 User Manual Direct
Allows the user to calibrate the displayed voltage value against a known source.
The module features five primary functions that can be programmed:
The unit uses four keys— [SET] , [SW1] , [+] , and [-] —to navigate the following menu options: : Function selection (F-01 to F-05). P-1 : Lower limit voltage setting (00.0V to 99.9V). P-2 : Upper limit voltage setting (00.0V to 99.9V). P-3 : Voltage calibration/correction. P-4 : Delay for relay activation (00.0s to 99.9s). P-5 : Delay for relay deactivation (00.0s to 99.9s). Preset Functions
Press and hold the button for 2 seconds until the display flashes a code (e.g., F-01 ).
to calibrate the voltage display by comparing it to a high-quality multimeter. dvb01 user manual
After adjusting parameters, hold [SET] for 1 second to save (the display will blink), or wait for the system to automatically save after inactivity. 3. Parameter Definitions The DVB01 utilizes several parameter settings, ranging from Description P-0 Function Select F-01 to F-05 (Defines working mode) P-1 Lower Limit Voltage 00.0V00.0 cap V 99.9V99.9 cap V (Lower threshold) P-2 Upper Limit Voltage 00.0V00.0 cap V 99.9V99.9 cap V (Upper threshold) P-3 Voltage Calibration 00.0V00.0 cap V 99.9V99.9 cap V (Calibrate display to real voltage) P-4 P1 Time Delay seconds (Delay before activating P1) P-5 P2 Time Delay seconds (Delay before activating P2) 4. DVB01 Function Descriptions (F-01 to F-05)
DC 5V, 12V, or 24V (depending on the specific module variant). Measurement Range: DC 0V to 100V with a precision of ±0.1Vplus or minus 0.1 cap V Load Capacity: Normally Open (NO): DC 0–30V/10A or AC 0–250V/10A. Normally Closed (NC): DC 0–28V/10A or AC 0–125V/10A.
The DVB01 terminal block is divided into two distinct sections: the (low current/signal) and the Relay Output side (load current). Input Terminals (Left Side / Control Signals)
Connect the DC voltage source you wish to measure. Allows the user to calibrate the displayed voltage
Connects to the load when the relay is triggered.
) allow for a delay in the relay action to prevent flickering caused by sudden, temporary voltage fluctuations.
Despite its user-friendly design, issues may arise during use. Here are some troubleshooting tips to help you resolve common problems:
The relay remains released while the voltage is safe inside the V1-V2 window. If the voltage drops below V2 OR rises above V1, the relay pulls in (closes NO). P-2 : Upper limit voltage setting (00
Below is a comprehensive guide on how to wire, program, and utilize the DVB01 effectively. 1. Technical Specifications
: All user-defined parameters are automatically saved and retained even when the power is disconnected. High-Load Capacity
The DVB01 device allows users to manage channels with ease. Here's how to search for channels, add new channels, and delete unwanted channels: