__hot__ — Mitutoyo Surftest Sv400 User Manual Full
Calibration must be performed daily or whenever the detector stylus is changed.
Configure these critical software settings based on your target specifications (ISO/JIS/ASME standards): Cut-off Length (
Once your unit is calibrated and your parameters are set, you are ready to test. Follow these steps for accurate, repeatable tracing:
The arithmetic mean of the absolute values of the profile deviations from the mean line.
Wipe down the exposed X-axis reference guide surfaces with a dry microfibre cloth to eliminate dust. Monthly Maintenance mitutoyo surftest sv400 user manual full
Press . The drive unit will traverse the calibration patch. Step 4: Save Compensation Coefficients
The SV-400 processes profile coordinates to output dozens of distinct parameters. Primary Parameters Defined
of portable surface roughness testers, which share a core set of features focused on skidless measurement and high-resolution data analysis. Wolverine Machine Core Measurement Capabilities Dual Measurement Modes : Switchable between
Heavy-duty granite base and manual or motorized vertical column to position the drive unit relative to the workpiece. Technical Specifications Summary Calibration must be performed daily or whenever the
SURFPAK (Windows-based parameters, analysis, and reporting). 2. Hardware Overview & Installation
This comprehensive guide serves as an operational manual, covering setup, calibration, measurement procedures, and troubleshooting. 1. System Overview and Component Identification
Mitutoyo Precision Roughness Reference Specimen (typically a glass or metallic plate with a known nominal value, e.g., Execution Workflow
The Mitutoyo Surftest SJ-400 series offers high-accuracy, skidless surface roughness and contour measurement, featuring a Wipe down the exposed X-axis reference guide surfaces
The vertical distance between the highest peak and lowest valley over the entire evaluation length. 7. Maintenance and Troubleshooting Preventative Maintenance Checklist
Follow this standardized workflow to execute a standard surface roughness profile measurement. Step 1: Configuring Measurement Parameters
: It supports 36 kinds of roughness parameters conforming to ISO, DIN, ANSI, and JIS standards. Pro Tips for Operation Leveling with D.A.T. Drive Alignment Tool (D.A.T.)
Connect the drive unit cable to the rear panel of the data processing console. Plug in the power cord and turn on the main power switch. 2. Calibration Procedure