Fanuc Ot - 900 Parameter List
Incorrect settings in the 900-series parameters can render the machine inoperable, cause servo crashes, or result in dangerous rapid movements. Always back up parameters before making changes. Do not alter these unless you are a qualified service engineer or have specific instructions from the machine tool builder.
: A "P/S 100" alarm will likely appear, which is normal when PWE is active.
Select the mode via the operator panel.
Activating an option parameter via the 900 series does not magically install physical hardware. For example, enabling a 4th axis (Parameter 901 Bit 6) without a physical 4th-axis drive card, servo amplifier, and cabling installed on the motherboard will cause an immediate axis communication alarm upon reboot.
It looks like you are diving into the "heart" of an older Fanuc control. The is a legendary workhorse, and Parameter 900 is a particularly interesting place to start because it marks the beginning of the Option Parameters (Bit patterns) in many memory layouts. fanuc ot 900 parameter list
Controls synchronization functions for dual-spindle setups. Parameter 901: Memory Capacity Options
Below is a list of frequently used 900-series parameters for the 0T control: | Parameter | Bit | Description | | :--- | :--- | :--- | | 0 | Canned Cycles (G70–G76) | | | 1 | G10 Program Input of Offset | | | 5 | Inch / Metric Conversion | | 1 | Tape Memory Addition (120M) | | | 5 | Chamfering and Corner Radius | | | 7 | Multiple Repetitive Canned Cycles | | 2 | Constant Surface Speed Control (G96/G97) | | | 6 | Custom Macro A | | 1 | X-Axis Mirror Image | | | 5 | Number of Programs (125) | | | 7 | Soft Keys below CRT | | 0 | Tool Geometry / Wear Offset | | 0 | Graphics Display | | 1 | Work Offsets (G54–G59) | | 2 | Rigid Tapping | | | 3 | Clock and Part Counters | How to Access and Edit 900 Parameters To modify these settings, you must first enable Parameter Write Enable (PWE) Fanuc Ot 900 Parameter List - Google Groups Incorrect settings in the 900-series parameters can render
Set PWE = 1 . The control will typically trigger a "P/S 100" alarm, which is normal during editing.
(Note: Combinations of these bits, along with Parameters 912 and 913, dictate maximum memory limits up to 320m or 512KB depending on the mainboard generation). Step-by-Step Guide: How to Change 900 Parameters : A "P/S 100" alarm will likely appear,
Modifying these parameters can unlock hidden features like macro programming, expanded memory, additional axes, or specific canned cycles without buying new hardware. Understanding Fanuc 0T 900 Parameters
Parameters in the 900-range (typically 900-939) are . Each parameter is an 8-bit byte (bits 0-7), where each bit acts as a switch (1 = Enabled, 0 = Disabled). How to Access and Change 900 Parameters Enter MDI Mode: Switch to MDI. Go to Parameters: Press the PARAM button.